Product image may be indicative and not an exact representation.
Additional Information
MCBS RCDS AND RCBOS, BRAND: NHP DIN-T, ITEM DESCRIPTION: DIN-T RCBO 1 POLE, 10KA, 30MA TYPE A ,D CURVE, 16 AMP, ADD-ON DEVICES (SIDE ADD-ON): PANELBOARD SWITCH, BUSBAR SYSTEM, BOTTOM: FORK, BUSBAR SYSTEM, BOTTOM: PIN, CENTRE TRIP POSITION: NO, COMPONENT TYPE MCBS RCDS RCBOS: RCBO, DEPTH, UNIT: 76, DIELECTRIC STRENGTH: 2500, ELECTRICAL SERVICE LIFE AT UN, IN: 10000, FLAMMABILITY RATING (UL94): UL 94 V-2, HEIGHT, UNIT: 125, IM, RATED RESIDUAL MAKING AND BREAKING CAPACITY: 10000, IN, RATED RESIDUAL OPERATING CURRENT: 30, ICN, RATED SHORT CIRCUIT CAPACITY: 10, IN, RATED CURRENT AT 30°C: 16, INSULATION RESISTANCE: 1000, IP RATING, INSIDE: IP40, IP RATING, OUTSIDE: IP20, ISOLATOR APPLICATION, IEC 60947-2: YES, MECHANICAL SERVICE LIFE: 20000, MOUNTING: DIN-35 RAIL MOUNT, NUMBER OF POLES VERSUS MODULES: 1, NUMBER OF POLES: 1, OPERATING TEMPERATURE (MAX.): 60, OPERATING TEMPERATURE (MIN.): -5, PAD LOCKABLE: YES, CAPTIVE AND NON-CAPTIVE (ORDERED SEPARATELY), RATED FREQUENCY: 50, RATED FREQUENCY: 60, RCD TYPE (AS/NZS 61008/61009): A, RELATIVE HUMIDITY, MAX: 95, SEALABLE: YES, SHOCK ACCELERATION (MAX.): 40, SHOCK DURATION (MAX.): 5, SHOCK VOLTAGE: 1.2/50MS@6KV, STORAGE TEMPERATURE (MAX.): 70, STORAGE TEMPERATURE (MIN.): -25, TIGHTENING TORQUE, BOTTOM, NOMINAL: 3, TIGHTENING TORQUE, TOP, NOMINAL: 3, TRIP CURVE: D, TRIP-FREE MECHANISM: YES, TRIPPING TIME AT IN, INSTANTANEOUS:, UBMAX, SERVICE VOLTAGE, AC, MAX: 255, UBMIN, SERVICE VOLTAGE, AC, MIN: 100, UI, RATED INSULATION VOLTAGE: 500, VIBRATION ACCELERATION (MAX.): 2, VIBRATION DURATION (MAX.): 30, VIBRATION FREQUENCY, OPERATIONAL (MAX.): 80, WEIGHT, UNIT: 35, WIDTH, UNIT: 18, WIRE / CONDUCTOR SIZE, BOTTOM, FLEXIBLE CABLE (MAX): 25 MM², WIRE / CONDUCTOR SIZE, BOTTOM, RIGID CABLE (MAX): 35 MM², WIRE / CONDUCTOR SIZE, TOP, FLEXIBLE CABLE (MAX): 16 MM², WIRE / CONDUCTOR SIZE, TOP, RIGID CABLE (MAX): 25 MM², FEATURES AND BENEFITS: IMPROVED IMMUNITY TO HARMONICS AVOIDING INCONVENIENT SERVICE INTERRUPTION, LARGE SELECTION OF CURRENT RATINGS FOR ALL COMMERCIAL AND INDUSTRIAL APPLICATIONS, VARIOUS RCD TYPES INCLUDING AC, A, S AND TYPE B ARE AVAILABLE ENSURING WHATEVER THE LOAD(S) CONNECTED, YOU AND/OR THE INSTALLATION IS PROTECTED FROM EARTH LEAKAGE CURRENTS, WIDE RANGE OF TRIP SENSITIVITY OPTIONS TO CHOOSE FROM WITH 10MA UP TO 500 MA RCDS COVERING ANY APPLICATION REQUIREMENT, 6 OR 10KA SHORT CIRCUIT CAPACITY AVAILABLE FOR RCBOS, COMPATIBILITY WITH A WIDE RANGE OF DIN-T MCB ACCESSORIES INCLUDING AUXILIARIES, SHUNT AND UNDERVOLTAGE TRIP, MOTOR OPERATOR, LOCKING DEVICES, POLE COVERS AND MORE, STANDARDS COMPLIANCE: DIN 40046, STANDARDS COMPLIANCE: IEC 60068-2, STANDARDS COMPLIANCE: IEC 60068-2-6, STANDARDS COMPLIANCE: IEC 60077-16-3, STANDARDS COMPLIANCE: IEC 60947-1, STANDARDS COMPLIANCE: UL 94 V-2, SERVICE INFORMATION: PRODUCT IS NOT REPAIRABLE